Programmable AC/DC Power Source
ES series

Single-phase 2 kVA to 20 kVA, Three-phase 6 kVA to 60 kVA. Single-/Three-phase switchable*.
AC output voltage: 0 to 150 V/0 to 300 V, Frequency: 5 Hz to 1100 Hz,
DC output voltage: 0 to + 203 V/0 to + 406 V
Component style allows expansion after being introduced.
Cabinet style is compact and requires small installation space.
Voltage dips, voltage variations, simultaneous sweeping of frequency and voltage.
Equipped with measurement function, protective circuit, remote sensing, and AGC function. External input available and peak current of 3.5 times of maximum rms value can be supplied.
Software (Immunity Test Software ES0406D *) that performs low frequency immunity test of IEC standard is available.
Performs power source harmonic measurement and various simulations. Furthermore, it can be used as CVCF for anechoic chamber or production line.
* option


Enriching Lineup in Two Styles to Choose from

Same functions and performance are provided in two styles.

ES series is available in two styles; Component style that is capacity-expandable with addition of a booster, and Cabinet style that is simple and requires small installation space. You can choose the one that suits your situation from our rich lineup.


Component Style Cabinet Style (S or L type)
Single-Phase
Systems
2 kVA to 20 kVA (Increment of 2 kVA)
Basic : ES2000S Single-phase master
(2 kVA)
ES2000B Booster (2 kVA) added
6 kVA to18 kVA (5 types)
6 kVA (ES6000S) S type x 1
8 kVA (ES8000S) S type x 1
10 kVA (ES10000S) L type x 1
12 kVA (E12000S) L type x 1
18 kVA (ES18000S) S type x 1 + L type x 1
Three-Phase
Systems
6 kVA to 60 kVA (Increment of 6 kVA)
Basic :
Combination of one unit of ES2000U
Three-phase master (2 kVA) and 2 units of ES2000P Three-phase slave (2 kVA).
Total of 6 kVA.
3 units of booster (2 kVA, ES2000B ) are added as output power increases
24 kVA, 36 kVA
24 kVA (ES24000T) S type x 1
36 kVA (ES36000T) L type x 1
Three-/
Single Phase
Systems
Three-phase 6kVA system
equipped with optional distribution unit
6 kVA, 12 kVA, 18 kVA
6 kVA (ES6000W) S type x 1
12 kVA (ES12000W) L type x 1
18 kVA (ES18000W) S type x 1+L type x 1
ES series cannot be used in combination with conventional model of 4400 series.



back