Lock-in Amplifier/Preamplifier
Digital Lock-in Amplifier
LI5660/LI5655/LI5650/LI5645

SPM (Scanning Probe Microscope) Signal Processing

Spectroscopic reflective measurement of materials
Scanning probe microscopes such as STM (scanning tunnel microscope) and AFM (atomic force microscope) use a nanoscale probe at the tip to scan the surface of a sample. The signal between the probe and the sample is detected to observe the electronic state and structure of the sample surface, as well as its physical and chemical properties.
Lock-in amplifiers are used to control the distance between the sample and probe.
The LI5600 series can also be used with high resonance frequency cantilever movement in the MHz range, and setting a smaller time constant (from 1 μs) allows high-speed scanning to generate images in a shorter time.
The synchronization filter can drastically reduce phase detection output ripples, resulting in much higher quality images, generated at a faster speed.
Lock-in amplifiers are also used for signal processing such as modulation signal demodulation with KFM (surface potential microscope) as well as STM and ATM.


Light Transmission Measurements (Suppression of Illuminant Fluctuation)

Spectroscopic reflective measurement of materials
Using both the dual-frequency simultaneous and fractional harmonic measurement functions allows fluctuation corrections of light sources and other sources using the dual beam method (ratio measurement) with a single LI5660/ LI5655/LI5650.
Applying negative feedback to the reference cell signal also stabilizes the strength of the light source.
The integral multiple (n x), integral inverse (1/m x) and fraction (n/m x) of the reference signal frequency can be configured, allowing it to be used easily with light chopper frequency ratios. When integral ratios are used, signals cannot be distinguished from harmonic components generated by distortion in the signal, however there is no impact on the harmonics if fraction ratios are used.
The 10 MHz synchronization function can also be used to synchronize operation with external signal generators, allowing detection of any two frequencies.
top of this page
Hall Coefficient Measurement (Difference Frequency Measurement)

Spectroscopic reflective measurement of materials
The hall voltage is proportional to the product of two signals (current and magnetic field), and its frequency is the difference frequency (and sum) of the two signals. Synchronizing an external signal source, which generates a current and magnetic field, with the LI5600 series at an external 10 MHz allows measurement of the difference frequency signal of any two frequencies without having to arrange an external reference signal (difference frequency).

top of this page
Other applications

ball Spectroscopy (material science using Auger electron spectroscopy, photoacoustic spectroscopy, Raman spectroscopy, etc.)
ball Measurement of optical properties (intensity, absorption, scattering, transmission, etc.)
ball Optical application measurements (optical gyro, detection of distance, speed, vibration, etc.)
ball Magnetic measurements (evaluation of magnetic materials, vibration-type magnetometer, magnetic detection using SQUID)
ball Evaluation of various sensors (measurements of physical quantities detected by optical, magnetic, and piezoelectric elements, chemical changes, etc.)
ball Null detection with impedance bridge
ball Impedance measurements (minute impedance, minute capacity, chemical impedance)
ball Thermal diffusivity measurement of thin film materials
ball Inelastic Electron Tunneling Spectroscopy (IETS Methos)
ball Measurement of TMR (Tunnel Magneto Resistance Effect) detail