The DP Series has
performance and
functions required of a
power supply
while meeting the unique
needs of each
customer.
Strong and smart —
this is an AC power
source for the
future.
|
|
|
|
Line-up
|
|
|
|
*1
Single-phase model ×2 units
*2 Single-phase
model ×3 units, 144kVA max.
*3
1-phase/1-phase 3-wire/3-phase
selectable
|
|
Single phase :
100V to 230V
Three phase 3 wire :
200V to 220V
Three phase 4 wire :
380V
* Power input depends
on the model. See the spec sheet for
details.
|
|
Output Characteristics
|
|
|
|
The DP series achieves stable output with
low distortion, and operates stably with
high-capacity capacitor loads. With a
variety of output modes and a wide output
range.
|
|
|
AC/DC modes: AC, ACDC, DC
|
|
AC
|
The signal source
and amplifier are
AC-coupled, and the
DC signal cannot be
output or set. The
lower limit of the
frequency setting
for the AC voltage
in INT mode is 40Hz.
|
ACDC
|
The signal source
and amplifier are
DC-coupled, and DC
signals and AC
signals including
low frequencies can
be output. The lower
limit of the
frequency setting
for AC voltage in
INT mode is
1Hz.
DC voltage setting
is possible only for
single-phase models
(including
single-phase mode
for multi-phase
models). DC voltage
cannot be set for
single-phase 3-wire
or three-phase
models(including
multi-phase mode).
|
DC
|
The signal source
and amplifier are
DC-coupled. The
voltage can be set
only for DC, and the
AC voltage is fixed
at 0V.
DC mode is available
only for
single-phase models
(including
single-phase mode
for multi-phase
models). DC mode
cannot be set for
single-phase
three-wire or
three-phase
(including
multi-phase model
mode).
|
|
|
|
|
Output voltage/frequency
|
|
|
|
100 V range
|
200 V range
|
Resolution
|
AC
|
Output voltage
|
0 V to 160V
|
0 V to 320V
|
0.1 V
|
Frequency
|
AC: 40Hz to
550Hz
ACDC: 1Hz to
550Hz
|
0.01Hz
|
DC
|
Output voltage
|
-227 V to +227V
|
-454 V to +454 V
|
0.1 V
|
|
|
|
|
Output voltage fluctuation: within
±0.15 V (75 V to150 V)/within
±0.30 V (150 V to 300
V) (DC, 45 Hz to 65 Hz if output
current is varied from 0% to 100% of maximum
current)
|
|
Maximum peak current: four times the maximum
current (RMS value) (corresponds to a
capacitor input rectified load with a crest
factor of 4)
|
|
Waveform distortion rate: 0.5% max.
|
|
|
Measurement
Functions |
|
|
|
In addition to voltage, current and
power, the DP series optionally supports
measurement of load power factor, crest
factor, and up to 40th-order harmonic
current. In addition, the series
supports measures to control
CO2 by displaying
CO2 emissions during
operation.
|
Measurement Items
|
|
Voltage:
RMS value, average DC value, peak value |
|
|
Load
power factor |
|
Current:
RMS value, average DC value, peak value,
peak hold value |
|
|
Crest
factor |
|
Power:
active power, apparent power, reactive power
|
|
|
Sync
frequency |
|
Harmonic
current: up to 40th order |
|
|
CO2 emissions |
|
|
Simple Operation
|
|
|
|
Panel operation is a breeze using the
large, easy-to-read display.
The design stresses improved ease-of-use
and work efficiency for users, with
features such as a function for
selecting three decided measurement
items and displaying them enlarged, and
remote operation using a remote
controller.
|
|
|
|