NF Corporation
network contact us site map
Google  
home about nf products support news
Measurement Instruments Power Supply and Power Control produts Function Modules Customized Products
home > Products > Power Supply and Power Control Products > AC Power Source > DP series
Product Information

AC Power Source
Programmable AC Power Source
DP series

standard to powerfully support various tests and measurements.

The DP Series has performance and functions required of a power supply
while meeting the unique needs of each customer.
Strong and smart — this is an AC power source for the future.

dp series


NF has knowledge and skill about AC power source and our DP Series incorporates new ideas while pursuing the high-quality, stable supply of power that is the fundamental role of any AC power source.

spacespacer
ball Output control employing our unique hybrid power control technology
ball User interface designed to take into account how each customer uses the equipment
ball Energy-saving design to efficiently supply power and improve equipment operability

 

* Line-up *

You can select the optimal power supply from a broad range of options, from single-phase 1.5 kVA to a maximum of three-phase 144 kVA.

DP series Line up (Approx.458KB)

 

ball
The lineup includes single-phase, single-phase 3-wire, three-phase and multi-phase ( single-phase, single-phase 3-wire, or three-phase selectable) models.
ball
A multi-phase system (single-phase 3-wire/three-phase) can be configured by connecting multiple units of the same single-phase model.
* Same model name with same ver. of firmware

  1.5 kVA 3 kVA 4.5 kVA 6 kVA 7.5 kVA 9 kVA 10.5 kVA 12 kVA 16 kVA 18 kVA 24 kVA 36 kVA 42 kVA 48 kVA
Single-phase available available available available available available available available available available available available available
Single-phase,
3-wire
*1
available available available available
Three-phase *2 available available

Multi-phase *3

available available available available available available available

*1  Single-phase model ×2 units
*2 Single-phase model ×3 units, 144kVA max.
*3 1-phase/1-phase 3-wire/3-phase selectable


ball
Power input

Single phase :

100V to 230V

Three phase 3 wire :

200V to 220V

Three phase 4 wire :

380V

* Power input depends on the model. See the spec sheet for details.

* Output Characteristics *

The DP series achieves stable output with low distortion, and operates stably with high-capacity capacitor loads. With a variety of output modes and a wide output range.
 
ball
AC/DC modes: AC, ACDC, DC
 
AC The signal source and amplifier are AC-coupled, and the DC signal cannot be output or set. The lower limit of the frequency setting for the AC voltage in INT mode is 40Hz.
ACDC The signal source and amplifier are DC-coupled, and DC signals and AC signals including low frequencies can be output. The lower limit of the frequency setting for AC voltage in INT mode is 1Hz.
DC voltage setting is possible only for single-phase models (including single-phase mode for multi-phase models). DC voltage cannot be set for single-phase 3-wire or three-phase models(including multi-phase mode).
DC The signal source and amplifier are DC-coupled. The voltage can be set only for DC, and the AC voltage is fixed at 0V.
DC mode is available only for single-phase models (including single-phase mode for multi-phase models). DC mode cannot be set for single-phase three-wire or three-phase (including multi-phase model mode).
 
ball
Output voltage/frequency
 
    100 V range 200 V range Resolution
AC Output voltage 0 V to 160V 0 V to 320V 0.1 V
Frequency
AC: 40Hz to 550Hz 
ACDC: 1Hz to 550Hz
0.01Hz
DC Output voltage -227 V to +227V -454 V to +454 V 0.1 V
 
ball
Output voltage fluctuation: within ±0.15 V (75 V to150 V)/within ±0.30 V (150 V to 300 V)
 (DC, 45 Hz to 65 Hz if output current is varied from 0% to 100% of maximum current)
ball
Maximum peak current: four times the maximum current (RMS value) (corresponds to a capacitor input rectified load with a crest factor of 4)
ball

Waveform distortion rate: 0.5% max.

space


* Measurement Functions *

In addition to voltage, current and power, the DP series optionally supports measurement of load power factor, crest factor, and up to 40th-order harmonic current. In addition, the series supports measures to control CO2 by displaying CO2 emissions during operation.

Measurement Items
ball
Voltage: RMS value, average DC value, peak value  
ball
Load power factor
ball
Current: RMS value, average DC value, peak value, peak hold value  
ball
Crest factor
ball
Power: active power, apparent power, reactive power  
ball
Sync frequency
ball
Harmonic current: up to 40th order  
ball
CO2 emissions


* Simple Operation *

Panel operation is a breeze using the large, easy-to-read display.
The design stresses improved ease-of-use and work efficiency for users, with features such as a function for selecting three decided measurement items and displaying them enlarged, and remote operation using a remote controller.

simple operation
space

back