NF DP020AGS VI tree.vi

The vi included in this driver is allocated in a diagram.


Connector Pane

NF DP020AGS VI tree.vi


Front Panel

NF DP020AGS VI tree.vi


Controls and Indicators


Block Diagram

NF DP020AGS VI tree.vi


NF DP020AGS GettingStarted CC.vi

Switch the output function mode to CC and Continuous, make the output setting, then turn on the output.

After that, use the measurement function to read the measured output value.


Connector Pane

NF DP020AGS GettingStarted CC.vi


Front Panel

NF DP020AGS GettingStarted CC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Initialize?[Initialize?]

Choose the presence of initialization.

cbool

Output(ON)[Output(ON)]

Output ON/OFF

0/OFF:Disable 1/ON:Enable

cbool

Close?[Close?]

Choose the presence of close.

cnclst

Output Set[Output Set]

Output setting

cnclst

Function Set[Function Set]

Waveform setting

ccclst

Limit Set[Limit Set]

Current Limiter Setting

cerrcodeclst

error out[error out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

ID[ID]

ID Check (T) the value of Yes when the ID will be output.

i1dnclst

Measure[Measure]

Measurement results are stored.

Results

Index0(Element0):L1Result Always

Index1(Element1):L2Result Only 1P3W or 3P4W Model

Index2(Element2):L3Result Only 3P4W Model

ierrcodeclst

Error Out[Error Out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.


Block Diagram

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi

NF DP020AGS GettingStarted CC.vi


NF DP020AGS GettingStarted CV.vi

Switch the output function mode to CV and Continuous, make the output setting, then turn on the output.

After that, use the measurement function to read the measured output value.


Connector Pane

NF DP020AGS GettingStarted CV.vi


Front Panel

NF DP020AGS GettingStarted CV.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Initialize?[Initialize?]

Choose the presence of initialization.

cbool

Output(ON)[Output(ON)]

Output ON/OFF

0/OFF:Disable 1/ON:Enable

cbool

Close?[Close?]

Choose the presence of close.

cnclst

Output Set[Output Set]

Output setting

cnclst

Function Set[Function Set]

Waveform setting

ccclst

Limit Set[Limit Set]

Current Limiter Setting

cerrcodeclst

error out[error out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

ID[ID]

ID Check (T) the value of Yes when the ID will be output.

i1dnclst

Measure[Measure]

Measurement results are stored.

Results

Index0(Element0):L1Result Always

Index1(Element1):L2Result Only 1P3W or 3P4W Model

Index2(Element2):L3Result Only 3P4W Model

ierrcodeclst

Error Out[Error Out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.


Block Diagram

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi

NF DP020AGS GettingStarted CV.vi


NF DP020AGS SequenceRun.vi

Switch the output function mode to Sequence, read the sequence data pre-stored in the main unit,and start the sequence execution. After that, use the measurement function to read the measuredoutput value.


Connector Pane

NF DP020AGS SequenceRun.vi


Front Panel

NF DP020AGS SequenceRun.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Initialize?[Initialize?]

cbool

Close?[Close?]

cerrcodeclst

error out[error out]

error out can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 1 to 5 Resolution:1

istr

ID[ID]

ID Check (T) the value of Yes when the ID will be output.

ierrcodeclst

Error Out[Error Out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

i1dnclst

Measure[Measure]

Measurement results are stored.

Results

Index0(Element0):L1Result Always

Index1(Element1):L2Result Only 1P3W or 3P4W Model

Index2(Element2):L3Result Only 3P4W Model


Block Diagram

NF DP020AGS SequenceRun.vi

NF DP020AGS SequenceRun.vi

NF DP020AGS SequenceRun.vi


NF DP020AGS SimulationRun.vi

Switch the output function mode to Simulation, read the simulation data pre-stored in the main unit, and start the power fluctuation simulation. After that, use the measurement function to read the measured output value.


Connector Pane

NF DP020AGS SimulationRun.vi


Front Panel

NF DP020AGS SimulationRun.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Initialize?[Initialize?]

cbool

Close?[Close?]

cerrcodeclst

error out[error out]

error out can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 1 to 5 Resolution:1

istr

ID[ID]

ID Check (T) the value of Yes when the ID will be output.

ierrcodeclst

Error Out[Error Out]

error out passes error or warning information out of a VI to be used by other VIs.Right-click the error out indicator on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

i1dnclst

Measure[Measure]

Measurement results are stored.

Results

Index0(Element0):L1Result Always

Index1(Element1):L2Result Only 1P3W or 3P4W Model

Index2(Element2):L3Result Only 3P4W Model


Block Diagram

NF DP020AGS SimulationRun.vi

NF DP020AGS SimulationRun.vi

NF DP020AGS SimulationRun.vi


NF DP020AGS Trig Seq Comp.vi

Compiles the sequence data


Connector Pane

NF DP020AGS Trig Seq Comp.vi


Front Panel

NF DP020AGS Trig Seq Comp.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Seq Comp.vi


NF DP020AGS Trig Seq Sel Exec.vi

Sets the sequence control


Connector Pane

NF DP020AGS Trig Seq Sel Exec.vi


Front Panel

NF DP020AGS Trig Seq Sel Exec.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Select(Stop)[Select(Stop)]

Sequence Control

STOP : Stop running

STARt : Start/resume running

HOLD : Suspend

BRAN1 : Branch 1

BRAN2 : Branch 2

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Seq Sel Exec.vi


NF DP020AGS Trig Sim Comp.vi

Compiles the simulation data


Connector Pane

NF DP020AGS Trig Sim Comp.vi


Front Panel

NF DP020AGS Trig Sim Comp.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Sim Comp.vi


NF DP020AGS Trig Sim Sel Exec.vi

Sets the simulation control


Connector Pane

NF DP020AGS Trig Sim Sel Exec.vi


Front Panel

NF DP020AGS Trig Sim Sel Exec.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Select(Stop)[Select(Stop)]

Simulation Control

Stop : Stop running

Start : Start running

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Sim Sel Exec.vi


NF DP020AGS Syst Conf Npu Err.vi

Gets the power unit in which an error occurs

It gets the power unit in which an error occurs from the L1, L2, and L3 phases.

The status of each phase is assigned for each bit as follows:

If an error occurs in a power unit, the corresponding bit returns 1.


Connector Pane

NF DP020AGS Syst Conf Npu Err.vi


Front Panel

NF DP020AGS Syst Conf Npu Err.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Npu Err.vi


NF DP020AGS Syst Conf Npu.vi

Obtain the connection configuration of L1 phase, L2 phase, and L3 phase.

The status of each phase is assigned to each bit as follows.


Connector Pane

NF DP020AGS Syst Conf Npu.vi


Front Panel

NF DP020AGS Syst Conf Npu.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Npu.vi


NF DP020AGS Outp.vi

Sets/gets the output on/off


Connector Pane

NF DP020AGS Outp.vi


Front Panel

NF DP020AGS Outp.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the output on/off

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp.vi

NF DP020AGS Outp.vi


NF DP020AGS Syst Conf Phas.vi

Gets the phase configuration

Sets the phase configuration (Limited to the model corresponding to change function)

Regarding the setting, there are the following restrictions.

The setting is error during the System Lock/warning.

The setting cannot be done in the Sequence or Simulation.

The setting cannot be done during the output on.

After changing the phase configuration and turning the power back on,

use the :SYSTem:MESSage? command to receive a message that the phase configuration has changed.


Connector Pane

NF DP020AGS Syst Conf Phas.vi


Front Panel

NF DP020AGS Syst Conf Phas.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Phase(single-phase(1P2W)))[Phase(single-phase(1P2W))]

phase configuration

0:single-phase 1:single-phase three-wire 2:three-phase

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Phas.vi

NF DP020AGS Syst Conf Phas.vi


NF DP020AGS Syst Kloc.vi

Sets/gets the key lock


Connector Pane

NF DP020AGS Syst Kloc.vi


Front Panel

NF DP020AGS Syst Kloc.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the key lock

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Kloc.vi

NF DP020AGS Syst Kloc.vi


NF DP020AGS Syst Wrel.vi

Sets the release of the warning


Connector Pane

NF DP020AGS Syst Wrel.vi


Front Panel

NF DP020AGS Syst Wrel.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Wrel.vi


NF DP020AGS Trig Seq Set.vi

Compile the Sequence setting parameter and switch to the Control mode


Connector Pane

NF DP020AGS Trig Seq Set.vi


Front Panel

NF DP020AGS Trig Seq Set.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Select(Stop)[Select(Stop)]

Sequence Control

Stop : Stop running

Start : Start/resume running

Hold : Suspend

Bran1 : Branch1

Bran2 : Branch2

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cbool

Output(ON)[Output(ON)]

Output ON/OFF

0/OFF:Disable 1/ON:Enable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Seq Set.vi


NF DP020AGS Trig Sim Set.vi

Compile the Simulation setting parameter and switch to the Control mode


Connector Pane

NF DP020AGS Trig Sim Set.vi


Front Panel

NF DP020AGS Trig Sim Set.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Select(Stop)[Select(Stop)]

Simulation Control

Stop : Stop running

Start : Start running

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cbool

Output(ON)[Output(ON)]

Output ON/OFF

0/OFF:Disable 1/ON:Enable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Sim Set.vi


NF DP020AGS Syst Conf Ext Pol.vi

Sets/gets the external control output polarity


Connector Pane

NF DP020AGS Syst Conf Ext Pol.vi


Front Panel

NF DP020AGS Syst Conf Ext Pol.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Polarity(Positive)[Polarity(Positive)]

Sets the external control output polarity

Positive :Positive

Negative :Negative

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Ext Pol.vi

NF DP020AGS Syst Conf Ext Pol.vi


NF DP020AGS Syst Conf Ext.vi

Sets/gets the external control status

Note that the external control input is ignored in the Remote state.


Connector Pane

NF DP020AGS Syst Conf Ext.vi


Front Panel

NF DP020AGS Syst Conf Ext.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cenum

State(OFF)[State(OFF)]

Sets the external control input

0:OFF(Disable) 1:ON(Enable)

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Ext.vi

NF DP020AGS Syst Conf Ext.vi


NF DP020AGS CC Volt Lim Peak High.vi

Sets/gets Voltage Limit (Peak Value <Maximum>)


Connector Pane

NF DP020AGS CC Volt Lim Peak High.vi


Front Panel

NF DP020AGS CC Volt Lim Peak High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Voltage Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Voltage(238)[Voltage(238)]

<Sets/gets the peak voltage limiter (positive) [V]>

Numeric Range:50 to 476 Resolution:1

Unit:[Vpk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Peak High.vi

NF DP020AGS CC Volt Lim Peak High.vi

NF DP020AGS CC Volt Lim Peak High.vi

NF DP020AGS CC Volt Lim Peak High.vi


NF DP020AGS CC Volt Lim Peak Low.vi

Sets/gets Voltage Limit (Peak Value <Minimum>)


Connector Pane

NF DP020AGS CC Volt Lim Peak Low.vi


Front Panel

NF DP020AGS CC Volt Lim Peak Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Voltage Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Voltage(-238.0)[Voltage(-238.0)]

<Peak voltage limiter (negative) [V]>

Numeric Range: -476 to -50 Resolution:1

Unit:[Vpk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Peak Low.vi

NF DP020AGS CC Volt Lim Peak Low.vi

NF DP020AGS CC Volt Lim Peak Low.vi

NF DP020AGS CC Volt Lim Peak Low.vi


NF DP020AGS Curr Lim Peak High.vi

Sets/gets Current Limit (Peak Value <Maximum>)


Connector Pane

NF DP020AGS Curr Lim Peak High.vi


Front Panel

NF DP020AGS Curr Lim Peak High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Current Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Current(42.0)[Current(42.0)]

<Sets/gets the peak current limiter (positive) [A]>

Numeric Range:5 to 756.0 Resolution:0.1

Unit:[Apk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Peak High.vi

NF DP020AGS Curr Lim Peak High.vi

NF DP020AGS Curr Lim Peak High.vi

NF DP020AGS Curr Lim Peak High.vi


NF DP020AGS Curr Lim Peak Low.vi

Sets/gets Current Limit (Peak Value <Minimum>)


Connector Pane

NF DP020AGS Curr Lim Peak Low.vi


Front Panel

NF DP020AGS Curr Lim Peak Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Current Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Current(-42.0)[Current(-42.0)]

<Peak current limiter (negative) [A]>

Numeric Range: -756.0 to -5 Resolution:0.1

Unit:[Apk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Peak Low.vi

NF DP020AGS Curr Lim Peak Low.vi

NF DP020AGS Curr Lim Peak Low.vi

NF DP020AGS Curr Lim Peak Low.vi


NF DP020AGS Freq Lim High.vi

Sets/gets the upper limit value [Hz] of the frequency setting range limit

The setting cannot be done in the Sequence and Simulation.

The setting can be made only in the AC-INT, AC-VCA, and ACDC-INT modes.


Connector Pane

NF DP020AGS Freq Lim High.vi


Front Panel

NF DP020AGS Freq Lim High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Frequency Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Frequency(550)[Frequency(550)]

<Upper[Hz]>

Numeric Range: 1.00 to 550 Resolution:0.01

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Freq Lim High.vi

NF DP020AGS Freq Lim High.vi

NF DP020AGS Freq Lim High.vi

NF DP020AGS Freq Lim High.vi


NF DP020AGS Freq Lim Low.vi

Sets/gets the lower limit value [Hz] of the frequency setting range limit

The setting cannot be done in the Sequence and Simulation.

The setting can be made only in the AC-INT, AC-VCA, and ACDC-INT modes.


Connector Pane

NF DP020AGS Freq Lim Low.vi


Front Panel

NF DP020AGS Freq Lim Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Frequency Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Frequency(1)[Frequency(1)]

<Lower[Hz]>

Numeric Range: 1.00 to 550 Resolution:0.01

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Freq Lim Low.vi

NF DP020AGS Freq Lim Low.vi

NF DP020AGS Freq Lim Low.vi

NF DP020AGS Freq Lim Low.vi


NF DP020AGS Volt Lim High.vi

Sets/gets the voltage setting range limit (peak value <maximum>)s


Connector Pane

NF DP020AGS Volt Lim High.vi


Front Panel

NF DP020AGS Volt Lim High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Limit Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Limit(227.0)[Limit(227.0)]

<Voltage(maximum)>

Numeric Range: 0.1 to 454.0 Resolution:0.1

Unit:[Vpk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Lim High.vi

NF DP020AGS Volt Lim High.vi

NF DP020AGS Volt Lim High.vi

NF DP020AGS Volt Lim High.vi


NF DP020AGS Volt Lim Low.vi

Sets/gets the voltage setting range limit (peak value <minimum>)


Connector Pane

NF DP020AGS Volt Lim Low.vi


Front Panel

NF DP020AGS Volt Lim Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Limit Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Limit(-227.0)[Limit(-227.0)]

<Voltage(Minimum)>

Numeric Range: -454.0 to -0.1 Resolution:0.1

Unit:[Vpk]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Lim Low.vi

NF DP020AGS Volt Lim Low.vi

NF DP020AGS Volt Lim Low.vi

NF DP020AGS Volt Lim Low.vi


NF DP020AGS CC Curr Lim Rms.vi

Sets/gets the effective current setting range limit (effective value)


Connector Pane

NF DP020AGS CC Curr Lim Rms.vi


Front Panel

NF DP020AGS CC Curr Lim Rms.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Limit Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Limit(20.00)[Limit(20.00)]

<Effective voltage setting>

Numeric Range: 0.01 to 180.0 Resolution:0.01

Unit:[Arms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Curr Lim Rms.vi

NF DP020AGS CC Curr Lim Rms.vi

NF DP020AGS CC Curr Lim Rms.vi

NF DP020AGS CC Curr Lim Rms.vi


NF DP020AGS CC Volt Lim Peak Hi Low.vi

Voltage limiter(Peak)


Connector Pane

NF DP020AGS CC Volt Lim Peak Hi Low.vi


Front Panel

NF DP020AGS CC Volt Lim Peak Hi Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cenum

Input Data Type(Input)[Input Data Low Type(Input)]

Specifies the value to be set.

input:Voltage Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Input Data Type(Input)[Input Data High Type(Input)]

Specifies the value to be set.

input:Voltage Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Voltage Low(-238.0)[Voltage Low(-238.0)]

<Peak voltage limiter (negative) [V]>

Numeric Range: -476 to -50 Resolution:1

Unit:[Vpk]

cdbl

Voltage High(238)[Voltage High(238)]

<Sets/gets the peak voltage limiter (positive) [V]>

Numeric Range:50 to 476 Resolution:1

Unit:[Vpk]

idbl

Query Limit High[Query Limit High]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query Limit Low[Query Limit Low]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Peak Hi Low.vi


NF DP020AGS CC Volt Lim Peak Mode.vi

Sets/gets the output off after the peak voltage limiter is activated


Connector Pane

NF DP020AGS CC Volt Lim Peak Mode.vi


Front Panel

NF DP020AGS CC Volt Lim Peak Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Continuous)[Mode(Continuous)]

Sets the output off after the peak voltage limiter is activated

Continuous : Continuous output

OFF : Output OFF

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Peak Mode.vi

NF DP020AGS CC Volt Lim Peak Mode.vi


NF DP020AGS CC Volt Lim Peak Time.vi

Sets/gets the time [s] before turning the output off after the peak voltage limiter is activated


Connector Pane

NF DP020AGS CC Volt Lim Peak Time.vi


Front Panel

NF DP020AGS CC Volt Lim Peak Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Time(1)[Time(1)]

<Time>

Numeric Range: 1 to 10 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Peak Time.vi

NF DP020AGS CC Volt Lim Peak Time.vi

NF DP020AGS CC Volt Lim Peak Time.vi

NF DP020AGS CC Volt Lim Peak Time.vi


NF DP020AGS CC Volt Lim Rms Mode.vi

Sets/gets the output off after the RMS voltage limiter is activated


Connector Pane

NF DP020AGS CC Volt Lim Rms Mode.vi


Front Panel

NF DP020AGS CC Volt Lim Rms Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Continuous)[Mode(Continuous)]

Sets the output off after the RMS voltage limiter is activated

Continuous : Continuous output

OFF : Output OFF

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Rms Mode.vi

NF DP020AGS CC Volt Lim Rms Mode.vi


NF DP020AGS CC Volt Lim Rms Time.vi

Sets/gets the time [s] before turning the output off after the RMS voltage limiter is activated


Connector Pane

NF DP020AGS CC Volt Lim Rms Time.vi


Front Panel

NF DP020AGS CC Volt Lim Rms Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Time(1)[Time(1)]

<Time>

Numeric Range: 1 to 10 Resolution:1

Unit:[s]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Rms Time.vi

NF DP020AGS CC Volt Lim Rms Time.vi

NF DP020AGS CC Volt Lim Rms Time.vi

NF DP020AGS CC Volt Lim Rms Time.vi


NF DP020AGS CC Volt Lim Rms.vi

Sets/gets the voltage effective value [Vrms] limiter


Connector Pane

NF DP020AGS CC Volt Lim Rms.vi


Front Panel

NF DP020AGS CC Volt Lim Rms.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Voltage Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Voltage(227)[Voltage(227)]

<Voltage Limiter>

Numeric Range: 10 to 454 Resolution:1

Unit:[Vrms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Volt Lim Rms.vi

NF DP020AGS CC Volt Lim Rms.vi

NF DP020AGS CC Volt Lim Rms.vi

NF DP020AGS CC Volt Lim Rms.vi


NF DP020AGS Curr Lim Peak Hi Low.vi

Current limiter(Peak)


Connector Pane

NF DP020AGS Curr Lim Peak Hi Low.vi


Front Panel

NF DP020AGS Curr Lim Peak Hi Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Limit High Type(Input)[Limit High Type(Input)]

Specifies the value to be set.

input:Current High Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Limit Low Type(Input)[Limit Low Type(Input)]

Specifies the value to be set.

input:Current Low Specified value

Max : Maximum Value

Min : Minimum Value

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cdbl

Current(-42.0)[Low Current(-42.0)]

<Peak current limiter (negative) [A]>

Numeric Range: -756.0 to -5 Resolution:0.1

Unit:[Apk]

cdbl

Current(42.0)[High Current(42.0)]

<Sets/gets the peak current limiter (positive) [A]>

Numeric Range:5 to 756.0 Resolution:0.1

Unit:[Apk]

idbl

Query Limit High[Query Limit High]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query Limit Low[Query Limit Low]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Peak Hi Low.vi


NF DP020AGS Curr Lim Peak Mode.vi

Sets/gets the output off after the peak current limiter is activated


Connector Pane

NF DP020AGS Curr Lim Peak Mode.vi


Front Panel

NF DP020AGS Curr Lim Peak Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Continuous)[Mode(Continuous)]

Sets the output off after the peak current limiter is activated

Continuous : Continuous output

OFF : Output OFF

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Peak Mode.vi

NF DP020AGS Curr Lim Peak Mode.vi


NF DP020AGS Curr Lim Peak Time.vi

Sets/gets the time [s] before turning the output off after the peak current limiter is activated


Connector Pane

NF DP020AGS Curr Lim Peak Time.vi


Front Panel

NF DP020AGS Curr Lim Peak Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Time(1)[Time(1)]

<Time>

Numeric Range: 1 to 10 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Peak Time.vi

NF DP020AGS Curr Lim Peak Time.vi

NF DP020AGS Curr Lim Peak Time.vi

NF DP020AGS Curr Lim Peak Time.vi


NF DP020AGS Curr Lim Rms Mode.vi

Sets/gets the output off after the RMS current limiter is activated


Connector Pane

NF DP020AGS Curr Lim Rms Mode.vi


Front Panel

NF DP020AGS Curr Lim Rms Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Continuous)[Mode(Continuous)]

Sets the output off after the RMS current limiter is activated

Continuous : Continuous output

OFF : Output OFF

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Rms Mode.vi

NF DP020AGS Curr Lim Rms Mode.vi


NF DP020AGS Curr Lim Rms Time.vi

Sets/gets the time [s] before turning the output off after the RMS current limiter is activated


Connector Pane

NF DP020AGS Curr Lim Rms Time.vi


Front Panel

NF DP020AGS Curr Lim Rms Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Time(1)[Time(1)]

<Time>

Numeric Range: 1 to 10 Resolution:1

Unit:[s]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Rms Time.vi

NF DP020AGS Curr Lim Rms Time.vi

NF DP020AGS Curr Lim Rms Time.vi

NF DP020AGS Curr Lim Rms Time.vi


NF DP020AGS Curr Lim Rms.vi

Sets/gets the current effective value [Arms] limiter


Connector Pane

NF DP020AGS Curr Lim Rms.vi


Front Panel

NF DP020AGS Curr Lim Rms.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Current Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Current(10.5)[Current(10.5)]

<Current Limiter>

Numeric Range: 1.0 to 189 Resolution:0.1

Unit:[Arms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Lim Rms.vi

NF DP020AGS Curr Lim Rms.vi

NF DP020AGS Curr Lim Rms.vi

NF DP020AGS Curr Lim Rms.vi


NF DP020AGS Freq Lim Hi Low.vi

Sets/gets the upper & lower limit value [Hz] of the frequency setting range limit

The setting cannot be done in the Sequence and Simulation.

The setting can be made only in the AC-INT, AC-VCA, and ACDC-INT modes.


Connector Pane

NF DP020AGS Freq Lim Hi Low.vi


Front Panel

NF DP020AGS Freq Lim Hi Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Limit High Type(Input)[Limit High Type(Input)]

Specifies the value to be set.

input:Limit High Frequency Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Limit Low Type(Input)[Limit Low Type(Input)]

Specifies the value to be set.

input:Limit Low Frequency Specified value

Max : Maximum Value

Min : Minimum Value

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cdbl

Frequency(550)[High Frequency(550)]

<Upper[Hz]>

Numeric Range: 1.00 to 550 Resolution:0.01

cdbl

Frequency(1)[Low Frequency(1)]

<Lower[Hz]>

Numeric Range: 1.00 to 550 Resolution:0.01

idbl

Query Limit High[Query Limit High]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query Limit Low[Query Limit Low]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Freq Lim Hi Low.vi


NF DP020AGS Volt Lim Hi Low.vi

Sets/gets the voltage setting range limit (peak value <maximum> & <minimum>)


Connector Pane

NF DP020AGS Volt Lim Hi Low.vi


Front Panel

NF DP020AGS Volt Lim Hi Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Limit High Type(Input)[Limit High Type(Input)]

Specifies the value to be set.

input:Volt Limit High Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Limit Low Type(Input)[Limit Low Type(Input)]

Specifies the value to be set.

input:Volt Limit Low Specified value

Max : Maximum Value

Min : Minimum Value

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cdbl

Limit(227.0)[Volt Limit High(227.0)]

<Voltage(maximum)>

Numeric Range: 0.1 to 454.0 Resolution:0.1

Unit:[Vpk]

cdbl

Limit(-227.0)[Volt Limit Low(-227.0)]

<Voltage(Minimum)>

Numeric Range: -454.0 to -0.1 Resolution:0.1

Unit:[Vpk]

idbl

Query Limit High[Query Limit High]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query Limit Low[Query Limit Low]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Lim Hi Low.vi


NF DP020AGS Volt Lim Rms.vi

Sets/gets the effective voltage setting range limit (effective value)


Connector Pane

NF DP020AGS Volt Lim Rms.vi


Front Panel

NF DP020AGS Volt Lim Rms.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Limit Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Limit(175.0)[Limit(175.0)]

<Effective voltage setting>

Numeric Range: 0.1 to 700.0 Resolution:0.1

Unit:[Vrms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Lim Rms.vi

NF DP020AGS Volt Lim Rms.vi

NF DP020AGS Volt Lim Rms.vi

NF DP020AGS Volt Lim Rms.vi


NF DP020AGS RCL.vi

Recalls from the setting memory


Connector Pane

NF DP020AGS RCL.vi


Front Panel

NF DP020AGS RCL.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

ci32

RCL(0)[RCL(0)]

Recalls from the setting memory

Basic Setting Memory number:0-30

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS RCL.vi


NF DP020AGS SAV.vi

This stores the current status information in memory. The memory storage ranges from 1 to 30.


Connector Pane

NF DP020AGS SAV.vi


Front Panel

NF DP020AGS SAV.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

ci32

SAV(1)[SAV(1)]

Stores to the setting memory

Basic Setting Memory number:1-30

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS SAV.vi


NF DP020AGS Outp Fall Enab.vi

Sets/gets whether to enable/disable soft stop function.


Connector Pane

NF DP020AGS Outp Fall Enab.vi


Front Panel

NF DP020AGS Outp Fall Enab.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets whether to enable/disable the Soft Stop

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Fall Enab.vi

NF DP020AGS Outp Fall Enab.vi


NF DP020AGS Outp Fall Time.vi

Set/get soft stop time[s]


Connector Pane

NF DP020AGS Outp Fall Time.vi


Front Panel

NF DP020AGS Outp Fall Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Time(1)[Time(1)]

<Time>

Numeric Range: 0.0 to 30.0 Resolution:0.1

Unit:[s]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Fall Time.vi

NF DP020AGS Outp Fall Time.vi

NF DP020AGS Outp Fall Time.vi

NF DP020AGS Outp Fall Time.vi


NF DP020AGS Outp Rise Enab.vi

Sets/gets whether to enable/disable soft start function.


Connector Pane

NF DP020AGS Outp Rise Enab.vi


Front Panel

NF DP020AGS Outp Rise Enab.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets whether to enable/disable the Soft Start

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Rise Enab.vi

NF DP020AGS Outp Rise Enab.vi


NF DP020AGS Outp Rise Time.vi

Set/get soft start time[s]


Connector Pane

NF DP020AGS Outp Rise Time.vi


Front Panel

NF DP020AGS Outp Rise Time.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Time Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Time(1)[Time(1)]

<Time>

Numeric Range: 0.0 to 30.0 Resolution:0.1

Time:[s]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Rise Time.vi

NF DP020AGS Outp Rise Time.vi

NF DP020AGS Outp Rise Time.vi

NF DP020AGS Outp Rise Time.vi


NF DP020AGS Phas Stop Enab.vi

Sets/gets whether to enable/disable the output off phase


Connector Pane

NF DP020AGS Phas Stop Enab.vi


Front Panel

NF DP020AGS Phas Stop Enab.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets whether to enable/disable the output off phase

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Stop Enab.vi

NF DP020AGS Phas Stop Enab.vi


NF DP020AGS Phas Stop.vi

Sets/gets the output off phase


Connector Pane

NF DP020AGS Phas Stop.vi


Front Panel

NF DP020AGS Phas Stop.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Phase(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Phase(0)[Phase(0)]

<Phase>

Numeric Range: 0.0 to 359.9 Resolution:0.1

Unit:[deg]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Stop.vi

NF DP020AGS Phas Stop.vi

NF DP020AGS Phas Stop.vi

NF DP020AGS Phas Stop.vi


NF DP020AGS CC Curr Offs.vi

Sets/gets the DC output current

The setting is error during the System Lock/warning.

The setting cannot be done in the Sequence and Simulation.

This command can be set in CC mode.


Connector Pane

NF DP020AGS CC Curr Offs.vi


Front Panel

NF DP020AGS CC Curr Offs.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset(DC)>

Numeric Range: -180.0 to 180.0 Resolution:0.01

Unit:[V]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Curr Offs.vi

NF DP020AGS CC Curr Offs.vi

NF DP020AGS CC Curr Offs.vi

NF DP020AGS CC Curr Offs.vi


NF DP020AGS CC Curr Rang.vi

Sets/gets the output range(CC)


Connector Pane

NF DP020AGS CC Curr Rang.vi


Front Panel

NF DP020AGS CC Curr Rang.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Range(10A)[Range(10A)]

Set the output range(CC)

10A:10A Range

20A:20A Range

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Curr Rang.vi

NF DP020AGS CC Curr Rang.vi


NF DP020AGS CC Curr.vi

Sets/gets the AC output current

The setting is error during the System Lock/warning.

The setting cannot be done in the Sequence and Simulation.

This command can be set in CC mode.


Connector Pane

NF DP020AGS CC Curr.vi


Front Panel

NF DP020AGS CC Curr.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Amplitude(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Amplitude(0)[Amplitude(0)]

<Current>

Numeric Range: 0.0 to 180.0 Resolution:0.01

Unit

SIN:[Arms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CC Curr.vi

NF DP020AGS CC Curr.vi

NF DP020AGS CC Curr.vi

NF DP020AGS CC Curr.vi


NF DP020AGS Freq.vi

Sets/gets the output frequency


Connector Pane

NF DP020AGS Freq.vi


Front Panel

NF DP020AGS Freq.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Frequency Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Frequency(50)[Frequency(50)]

<Frequency>

Numeric Range: 1.00 (ACDC)/40.00 (AC) to 550

Resolution:0.01

Unit:[Hz]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Freq.vi

NF DP020AGS Freq.vi

NF DP020AGS Freq.vi

NF DP020AGS Freq.vi


NF DP020AGS Func Csin Cfac.vi

Sets/gets the clipped sine wave crest factor


Connector Pane

NF DP020AGS Func Csin Cfac.vi


Front Panel

NF DP020AGS Func Csin Cfac.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Cfactor(1.1) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Cfactor(1.1)[Cfactor(1.1)]

<Crest factor>

Numeric Range: 1.10 to 1.41 Resolution:0.01

cenum

Function(CLP1)[Function(CLP1)]

Clip Setting

CLP1 :Clipped Sine wave 1

CLP2 :Clipped Sine wave 2

CLP3 :Clipped Sine wave 3

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Func Csin Cfac.vi

NF DP020AGS Func Csin Cfac.vi

NF DP020AGS Func Csin Cfac.vi

NF DP020AGS Func Csin Cfac.vi


NF DP020AGS Func Csin Clip.vi

Sets/gets the clipped sine wave clip ratio


Connector Pane

NF DP020AGS Func Csin Clip.vi


Front Panel

NF DP020AGS Func Csin Clip.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Clip(40) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Clip(40)[Clip(40)]

<Clip Ratio>

Numeric Range: 40.0 to 100.0 Resolution:0.1

cenum

Function(CLP1)[Function(CLP1)]

Clip Setting

CLP1 :Clipped Sine wave 1

CLP2 :Clipped Sine wave 2

CLP3 :Clipped Sine wave 3

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Func Csin Clip.vi

NF DP020AGS Func Csin Clip.vi

NF DP020AGS Func Csin Clip.vi

NF DP020AGS Func Csin Clip.vi


NF DP020AGS Func Csin Type.vi

Sets/gets the clipped sine wave setting type


Connector Pane

NF DP020AGS Func Csin Type.vi


Front Panel

NF DP020AGS Func Csin Type.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Function(CLP1)[Function(CLP1)]

Clip Setting

CLP1 :Clipped Sine wave 1

CLP2 :Clipped Sine wave 2

CLP3 :Clipped Sine wave 3

cenum

Type(Cfactor)[Type(Cfactor)]

Clipped Sine Wave Setting

Cfactor : Crest factor

CLIP : Clipped

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Func Csin Type.vi

NF DP020AGS Func Csin Type.vi


NF DP020AGS Func.vi

Sets/gets the output waveform


Connector Pane

NF DP020AGS Func.vi


Front Panel

NF DP020AGS Func.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Function(Sine)[Function(Sine)]

Waveform setting

Sine : Sine Wave

CLP1 : Clipped Sine Wave1

CLP2 : Clipped Sine Wave2

CLP3 : Clipped Sine Wave3

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Func.vi

NF DP020AGS Func.vi


NF DP020AGS Mode.vi

Sets/gets the operation mode

The setting is error during the System Lock/warning.

When the output function is the Sequence, only INT can be selected as the signal source.

When the output function is the Simulation, only the ACDC-INT mode can be selected as the operation mode.


Connector Pane

NF DP020AGS Mode.vi


Front Panel

NF DP020AGS Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(AC_INT)[Mode(AC_INT)]

AC/DC Mode Setting

AC_INT

AC_VCA

AC_SYNC

DC_INT

DC_VCA

ACDC_INT

ACDC_SYNC

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Mode.vi

NF DP020AGS Mode.vi


NF DP020AGS Outp Fall.vi

Sets/gets whether to enable/disable soft stop function & soft stop time.


Connector Pane

NF DP020AGS Outp Fall.vi


Front Panel

NF DP020AGS Outp Fall.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Fall Time Data Type(Input)]

Specifies the value to be set.

input:Time Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Fall Time(1)[Fall Time(1)]

<Time>

Numeric Range: 0.0 to 30.0 Resolution:0.1

Unit:[s]

cbool

State(ON)[Fall State(ON)]

Sets whether to enable/disable the Soft Stop

0/OFF:Disable 1/ON:Enable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Fall Time Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

ii32

Query[Fall State Query]

Store the query results.

Read(F)

True : Query Results

False : Disable


Block Diagram

NF DP020AGS Outp Fall.vi


NF DP020AGS Outp Rise.vi

Sets/gets whether to enable/disable soft start function & soft start time.


Connector Pane

NF DP020AGS Outp Rise.vi


Front Panel

NF DP020AGS Outp Rise.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Rise Time Data Type(Input)]

Specifies the value to be set.

input:Time Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Rise Time(1)[Rise Time(1)]

<Time>

Numeric Range: 0.0 to 30.0 Resolution:0.1

Unit:[s]

cbool

State(ON)[Rise State(ON)]

Sets whether to enable/disable the Soft Start

0/OFF:Disable 1/ON:Enable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Rise Time Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

ii32

Query[Rise State Query]

Store the query results.

Read(F)

True : Query Results

False : Disable


Block Diagram

NF DP020AGS Outp Rise.vi


NF DP020AGS Phas Mode.vi

Sets/gets the balanced mode


Connector Pane

NF DP020AGS Phas Mode.vi


Front Panel

NF DP020AGS Phas Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Balance)[Mode(Balance)]

Balance Mode

Balance :Balance Mode

UnBalance :Unbalance Mode

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Mode.vi

NF DP020AGS Phas Mode.vi


NF DP020AGS Phas Phas.vi

Sets/gets the phase angle

The setting cannot be done in the single-phase.


Connector Pane

NF DP020AGS Phas Phas.vi


Front Panel

NF DP020AGS Phas Phas.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Phase(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Phase(0)[Phase(0)]

<Angle>

Phase angle: 0.0 to 359.9, Resolution 0.1 (polyphase system)

cenum

Target(L1)[Target(L1)]

<Phase angle>

L1 : Phase angle L1

L2 : Phase angle L2

L3 : Phase angle L3

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Phas.vi

NF DP020AGS Phas Phas.vi

NF DP020AGS Phas Phas.vi

NF DP020AGS Phas Phas.vi


NF DP020AGS Phas Star.vi

Sets/gets the output on phase


Connector Pane

NF DP020AGS Phas Star.vi


Front Panel

NF DP020AGS Phas Star.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Phase(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Phase(0)[Phase(0)]

<Phase>

Numeric Range: 0.0 to 359.9 Resolution:0.1

Unit:[deg]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Star.vi

NF DP020AGS Phas Star.vi

NF DP020AGS Phas Star.vi

NF DP020AGS Phas Star.vi


NF DP020AGS Phas Stop Set.vi

Sets/gets whether to enable/disable the output off & output off phase


Connector Pane

NF DP020AGS Phas Stop Set.vi


Front Panel

NF DP020AGS Phas Stop Set.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets whether to enable/disable the output off phase

0/OFF:Disable 1/ON:Enable

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Phase(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Phase(0)[Phase(0)]

<Phase>

Numeric Range: 0.0 to 359.9 Resolution:0.1

Unit:[deg]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Stop Phase State[Stop Phase State]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Stop Phase[Stop Phase]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Phas Stop Set.vi


NF DP020AGS Volt Offs.vi

Sets/gets the DC output voltage


Connector Pane

NF DP020AGS Volt Offs.vi


Front Panel

NF DP020AGS Volt Offs.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset(DC)>

Numeric Range: -908.0 to 908.0 Resolution:0.1

Unit:[V]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Offs.vi

NF DP020AGS Volt Offs.vi

NF DP020AGS Volt Offs.vi

NF DP020AGS Volt Offs.vi


NF DP020AGS Volt Rang.vi

Set/get the output range(CV)


Connector Pane

NF DP020AGS Volt Rang.vi


Front Panel

NF DP020AGS Volt Rang.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Range(100V)[Range(100V)]

Set the output range

100V:100V Range

200V:200V Range

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Rang.vi

NF DP020AGS Volt Rang.vi


NF DP020AGS Volt.vi

Sets/gets the AC output voltage


Connector Pane

NF DP020AGS Volt.vi


Front Panel

NF DP020AGS Volt.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Amplitude(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Amplitude(0)[Amplitude(0)]

<Voltage>

Numeric Range: 0.0 to 700.0 Resolution:0.1

Unit

SIN CLP:[Vrms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt.vi

NF DP020AGS Volt.vi

NF DP020AGS Volt.vi

NF DP020AGS Volt.vi


NF DP020AGS Trac Seq Cle.vi

Initializes the sequence data


Connector Pane

NF DP020AGS Trac Seq Cle.vi


Front Panel

NF DP020AGS Trac Seq Cle.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Memory(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 0 to 5 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trac Seq Cle.vi

NF DP020AGS Trac Seq Cle.vi

NF DP020AGS Trac Seq Cle.vi


NF DP020AGS Trac Seq Rec.vi

Reads the sequence data


Connector Pane

NF DP020AGS Trac Seq Rec.vi


Front Panel

NF DP020AGS Trac Seq Rec.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Memory(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 1 to 5 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trac Seq Rec.vi

NF DP020AGS Trac Seq Rec.vi

NF DP020AGS Trac Seq Rec.vi


NF DP020AGS Trac Sim Cle.vi

Initializes the simulation data


Connector Pane

NF DP020AGS Trac Sim Cle.vi


Front Panel

NF DP020AGS Trac Sim Cle.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Memory(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 0 to 5 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trac Sim Cle.vi

NF DP020AGS Trac Sim Cle.vi

NF DP020AGS Trac Sim Cle.vi


NF DP020AGS Trac Sim Rec.vi

Reads the simulation data


Connector Pane

NF DP020AGS Trac Sim Rec.vi


Front Panel

NF DP020AGS Trac Sim Rec.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Memory(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Memory(1)[Memory(1)]

<Memory>

Numeric Range: 1 to 5 Resolution:1

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trac Sim Rec.vi

NF DP020AGS Trac Sim Rec.vi

NF DP020AGS Trac Sim Rec.vi


NF DP020AGS Trig Pol.vi

Sets/gets the trigger output polarity


Connector Pane

NF DP020AGS Trig Pol.vi


Front Panel

NF DP020AGS Trig Pol.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Slope(Positive)[Slope(Positive)]

Trig slope

Positive :Rising

Negative :Falling

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Pol.vi

NF DP020AGS Trig Pol.vi


NF DP020AGS Trig Widt.vi

Sets/gets the trigger output pulse width


Connector Pane

NF DP020AGS Trig Widt.vi


Front Panel

NF DP020AGS Trig Widt.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Width Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Width(10.0)[Width(10.0)]

<Trig width>

Trigger output pulse width: 0.1 to 10.0, Resolution 0.1

Unit:[ms]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Trig Widt.vi

NF DP020AGS Trig Widt.vi

NF DP020AGS Trig Widt.vi

NF DP020AGS Trig Widt.vi


NF DP020AGS Meas Conf Sens.vi

Sets/gets the remote sensing


Connector Pane

NF DP020AGS Meas Conf Sens.vi


Front Panel

NF DP020AGS Meas Conf Sens.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cenum

State(OFF)[State(OFF)]

Sets the remote sensing

0:OFF(Disable)

1:ON(Enable)

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Conf Sens.vi

NF DP020AGS Meas Conf Sens.vi


NF DP020AGS Outp OFFI.vi

Sets/gets high impedance output off function


Connector Pane

NF DP020AGS Outp OFFI.vi


Front Panel

NF DP020AGS Outp OFFI.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets high impedance output off

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp OFFI.vi

NF DP020AGS Outp OFFI.vi


NF DP020AGS Outp Rel.vi

Sets/gets the output relay control


Connector Pane

NF DP020AGS Outp Rel.vi


Front Panel

NF DP020AGS Outp Rel.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the output relay control

0/OFF:Enable 1/ON:Disable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Rel.vi

NF DP020AGS Outp Rel.vi


NF DP020AGS Syst Conf Cons.vi

Sets/gets the CV/CC Mode


Connector Pane

NF DP020AGS Syst Conf Cons.vi


Front Panel

NF DP020AGS Syst Conf Cons.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(CV)[Mode(CV)]

CV/CC Mode

CV : Constant Voltage

CC : Constant Current

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf Cons.vi

NF DP020AGS Syst Conf Cons.vi


NF DP020AGS Syst Conf.vi

Sets/gets the output function


Connector Pane

NF DP020AGS Syst Conf.vi


Front Panel

NF DP020AGS Syst Conf.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Continuous)[Mode(Continuous)]

Output function

Continuous : Continuous Output

Sequence : Sequence

Simulation : Simulation

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Conf.vi

NF DP020AGS Syst Conf.vi


NF DP020AGS Meas Curr Ave.vi

Gets the output current average value [A]


Connector Pane

NF DP020AGS Meas Curr Ave.vi


Front Panel

NF DP020AGS Meas Curr Ave.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Ave.vi


NF DP020AGS Meas Curr Cfac.vi

Gets the output current crest factor


Connector Pane

NF DP020AGS Meas Curr Cfac.vi


Front Panel

NF DP020AGS Meas Curr Cfac.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Cfac.vi


NF DP020AGS Meas Curr Harm Enab.vi

Sets/gets whether to enable/disable the harmonic current measurement.

If harmonic current measurement is enabled with this command, harmonic voltage measurement will be disabled.

This command was prepared for the past DP series.


Connector Pane

NF DP020AGS Meas Curr Harm Enab.vi


Front Panel

NF DP020AGS Meas Curr Harm Enab.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets whether to enable/disable the harmonic measurement

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Harm Enab.vi

NF DP020AGS Meas Curr Harm Enab.vi


NF DP020AGS Meas Curr Harm Rat.vi

Gets the harmonic current percentage [%]


Connector Pane

NF DP020AGS Meas Curr Harm Rat.vi


Front Panel

NF DP020AGS Meas Curr Harm Rat.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Page(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Page(1)[Page(1)]

<Harmonic Current Percentage>

1(order 1 to 10)|2(order 11 to 20)|3(order 21 to 30)|4(order 31 to 40)|5(order 41 to 50)

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Harm Rat.vi

NF DP020AGS Meas Curr Harm Rat.vi

NF DP020AGS Meas Curr Harm Rat.vi


NF DP020AGS Meas Curr Harm.vi

Gets the harmonic current [Arms]


Connector Pane

NF DP020AGS Meas Curr Harm.vi


Front Panel

NF DP020AGS Meas Curr Harm.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Page(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Page(1)[Page(1)]

<Harmonic current[Arms]>

1(order 1 to 10)|2 (order 11 to 20)|3(order 21 to 30)|4(order 31 to 40)|5(order 41 to 50)

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Harm.vi

NF DP020AGS Meas Curr Harm.vi

NF DP020AGS Meas Curr Harm.vi


NF DP020AGS Meas Curr High.vi

Gets the output current maximum peak value [Apk]


Connector Pane

NF DP020AGS Meas Curr High.vi


Front Panel

NF DP020AGS Meas Curr High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr High.vi


NF DP020AGS Meas Curr Low.vi

Gets the output current minimum peak value [Apk]


Connector Pane

NF DP020AGS Meas Curr Low.vi


Front Panel

NF DP020AGS Meas Curr Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr Low.vi


NF DP020AGS Meas Curr.vi

Gets the output current effective value [Arms]


Connector Pane

NF DP020AGS Meas Curr.vi


Front Panel

NF DP020AGS Meas Curr.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Curr.vi


NF DP020AGS Meas Pow App.vi

Gets the apparent power [VA]


Connector Pane

NF DP020AGS Meas Pow App.vi


Front Panel

NF DP020AGS Meas Pow App.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Pow App.vi


NF DP020AGS Meas Pow Pfac.vi

Gets the power factor


Connector Pane

NF DP020AGS Meas Pow Pfac.vi


Front Panel

NF DP020AGS Meas Pow Pfac.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Pow Pfac.vi


NF DP020AGS Meas Pow.vi

Gets the active power [W]


Connector Pane

NF DP020AGS Meas Pow.vi


Front Panel

NF DP020AGS Meas Pow.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Pow.vi


NF DP020AGS Meas Volt Ave.vi

Gets the output voltage average value [V]


Connector Pane

NF DP020AGS Meas Volt Ave.vi


Front Panel

NF DP020AGS Meas Volt Ave.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt Ave.vi


NF DP020AGS Meas Volt Cfac.vi

Gets the output voltage crest factor


Connector Pane

NF DP020AGS Meas Volt Cfac.vi


Front Panel

NF DP020AGS Meas Volt Cfac.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt Cfac.vi


NF DP020AGS Meas Volt Harm Rat.vi

Gets the harmonic voltage percentage [%]


Connector Pane

NF DP020AGS Meas Volt Harm Rat.vi


Front Panel

NF DP020AGS Meas Volt Harm Rat.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Page(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Page(1)[Page(1)]

<Harmonic Voltage Percentage>

1(order 1 to 10)|2(order 11 to 20)|3(order 21 to 30)|4(order 31 to 40)|5(order 41 to 50)

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt Harm Rat.vi

NF DP020AGS Meas Volt Harm Rat.vi

NF DP020AGS Meas Volt Harm Rat.vi


NF DP020AGS Meas Volt Harm.vi

Gets the harmonic Volage [Vrms]


Connector Pane

NF DP020AGS Meas Volt Harm.vi


Front Panel

NF DP020AGS Meas Volt Harm.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Page(1) Specified value

Max : Maximum Value

Min : Minimum Value

ci32

Page(1)[Page(1)]

<Harmonic voltage[Vrms]>

1(order 1 to 10)|2 (order 11 to 20)|3(order 21 to 30)|4(order 31 to 40)|5(order 41 to 50)

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt Harm.vi

NF DP020AGS Meas Volt Harm.vi

NF DP020AGS Meas Volt Harm.vi


NF DP020AGS Meas Volt High.vi

Gets the voltage maximum value [Vpk]


Connector Pane

NF DP020AGS Meas Volt High.vi


Front Panel

NF DP020AGS Meas Volt High.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt High.vi


NF DP020AGS Meas Volt Low.vi

Gets the voltage minimum value [Vpk]


Connector Pane

NF DP020AGS Meas Volt Low.vi


Front Panel

NF DP020AGS Meas Volt Low.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt Low.vi


NF DP020AGS Meas Volt.vi

Gets the output voltage effective value [Vrms]


Connector Pane

NF DP020AGS Meas Volt.vi


Front Panel

NF DP020AGS Meas Volt.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Volt.vi


NF DP020AGS Harm Type.vi

Sets/gets the harmonic measurement type


Connector Pane

NF DP020AGS Harm Type.vi


Front Panel

NF DP020AGS Harm Type.vi


Controls and Indicators

cvsrn

VISAsession

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Type(Current)

Harmonic Measurement Type

Current : Harmonic current type

Voltage : Harmonic voltage type

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Harm Type.vi

NF DP020AGS Harm Type.vi


NF DP020AGS Meas Freq.vi

Gets the synchronization signal source frequency [Hz]

If overrange occurs, returns 9999999.

If the measurement conditions are not met, 99999999 is returned.


Connector Pane

NF DP020AGS Meas Freq.vi


Front Panel

NF DP020AGS Meas Freq.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Freq.vi


NF DP020AGS Curr Adj Offs AC.vi

Sets/gets the DC offset Current adjustment value [mA] in the AC mode


Connector Pane

NF DP020AGS Curr Adj Offs AC.vi


Front Panel

NF DP020AGS Curr Adj Offs AC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset>

Numeric Range: -1800 to 1800 Resolution:1

-200xN ~ 200xN

N represents the Number of units per phase.

Unit:[mA]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Adj Offs AC.vi

NF DP020AGS Curr Adj Offs AC.vi

NF DP020AGS Curr Adj Offs AC.vi

NF DP020AGS Curr Adj Offs AC.vi


NF DP020AGS Curr Adj Offs DC.vi

Sets/gets the DC offset Current adjustment value [mA] in the ACDC and DC modes


Connector Pane

NF DP020AGS Curr Adj Offs DC.vi


Front Panel

NF DP020AGS Curr Adj Offs DC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset>

Numeric Range: -3600 to 3600 Resolution:1

-400xN ~ 400xN

N represents the Number of units per phase.

Unit:[mA]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Adj Offs DC.vi

NF DP020AGS Curr Adj Offs DC.vi

NF DP020AGS Curr Adj Offs DC.vi

NF DP020AGS Curr Adj Offs DC.vi


NF DP020AGS Volt Adj Offs AC.vi

Sets/gets the DC offset voltage adjustment value [mV] in the AC mode


Connector Pane

NF DP020AGS Volt Adj Offs AC.vi


Front Panel

NF DP020AGS Volt Adj Offs AC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset>

Numeric Range: -50 to 50.0 Resolution:0.1

Unit:[mV]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Adj Offs AC.vi

NF DP020AGS Volt Adj Offs AC.vi

NF DP020AGS Volt Adj Offs AC.vi

NF DP020AGS Volt Adj Offs AC.vi


NF DP020AGS Volt Adj Offs DC.vi

Sets/gets the DC offset voltage adjustment value [mV] in the ACDC and DC modes


Connector Pane

NF DP020AGS Volt Adj Offs DC.vi


Front Panel

NF DP020AGS Volt Adj Offs DC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

Offset(0)[Offset(0)]

<Offset>

Numeric Range: -250 to 250 Resolution:1

Unit:[mV]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Adj Offs DC.vi

NF DP020AGS Volt Adj Offs DC.vi

NF DP020AGS Volt Adj Offs DC.vi

NF DP020AGS Volt Adj Offs DC.vi


NF DP020AGS Curr Adj Offs AC DC.vi

Sets/gets the DC offset current adjustment value [mA] in the AC mode and

the DC offset current adjustment value [mA] in the ACDC and DC modes


Connector Pane

NF DP020AGS Curr Adj Offs AC DC.vi


Front Panel

NF DP020AGS Curr Adj Offs AC DC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

AC Offset Type(Input)[AC Offset Type(Input)]

Specifies the value to be set.

inputAC Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cenum

DC Offset Type(Input)[DC Offset Type(Input)]

Specifies the value to be set.

input:DC Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

cdbl

Offset(0)[AC Offset(0)]

<Offset>

Numeric Range: -1800 to 1800 Resolution:1

-200xN ~ 200xN

N represents the Number of units per phase.

Unit:[mA]

cdbl

Offset(0)[DC Offset(0)]

<Offset>

Numeric Range: -3600 to 3600 Resolution:1

-400xN ~ 400xN

N represents the Number of units per phase.

Unit:[mA]

idbl

Query AC Offset[Query AC Offset]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query DC Offset[Query DC Offset]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Curr Adj Offs AC DC.vi


NF DP020AGS Outp Acal.vi

Sets/gets the Autocal


Connector Pane

NF DP020AGS Outp Acal.vi


Front Panel

NF DP020AGS Outp Acal.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the Autocal

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Acal.vi

NF DP020AGS Outp Acal.vi


NF DP020AGS Outp AGC.vi

Sets/gets the AGC


Connector Pane

NF DP020AGS Outp AGC.vi


Front Panel

NF DP020AGS Outp AGC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the AGC

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp AGC.vi

NF DP020AGS Outp AGC.vi


NF DP020AGS Volt Adj Offs AC DC.vi

Sets/gets the DC offset voltage adjustment value [mV] in the AC mode and

the DC offset voltage adjustment value [mV] in the ACDC and DC modes


Connector Pane

NF DP020AGS Volt Adj Offs AC DC.vi


Front Panel

NF DP020AGS Volt Adj Offs AC DC.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

AC Offset Type(Input)[Ac Offset Type(Input)]

Specifies the value to be set.

inputAC Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

AC Offset(0)[AC Offset(0)]

<Offset>

Numeric Range: -50.0 to 50.0 Resolution:0.1

Unit:[mV]

cenum

DC Offset Type(Input)[DC Offset Type(Input)]

Specifies the value to be set.

input:DC Offset(0) Specified value

Max : Maximum Value

Min : Minimum Value

cdbl

DC Offset(0)[DC Offset(0)]

<Offset>

Numeric Range: -250 to 250 Resolution:1

Unit:[mV]

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query AC Offset[Query AC Offset]

Store the query results.

Read(F)

True : Query Results

False : Disable

idbl

Query DC Offset[Query DC Offset]

Store the query results.

Read(F)

True : Query Results

False : Disable

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Volt Adj Offs AC DC.vi


NF DP020AGS Outp Mon Mode.vi

Sets/gets the monitor output


Connector Pane

NF DP020AGS Outp Mon Mode.vi


Front Panel

NF DP020AGS Outp Mon Mode.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Mode(Current)[Mode(Current)]

Monitor output

Current : Current monitor output mode

SCurrent : Single Current monitor output mode

Voltage : Voltage monitor output mode

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query[Query]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Mon Mode.vi

NF DP020AGS Outp Mon Mode.vi


NF DP020AGS CLS.vi

Clears event register and error queue.


Connector Pane

NF DP020AGS CLS.vi


Front Panel

NF DP020AGS CLS.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS CLS.vi


NF DP020AGS IDN.vi

Query ID


Connector Pane

NF DP020AGS IDN.vi


Front Panel

NF DP020AGS IDN.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

istr

Query IDN[Query IDN]

Store the query results.

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS IDN.vi


NF DP020AGS Inst Nsel.vi

Sets/gets the output phase setting (phase number)

It specifies the phase to set/get by the SOURce subsystem command.

It does not affect the phase specification by the SOURce:SEQuence subsystem.

For single-phase, only 0 and 1 can be set.

For single-phase three-wire, 0, 1, 2, and 4 can be set.


Connector Pane

NF DP020AGS Inst Nsel.vi


Front Panel

NF DP020AGS Inst Nsel.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Number(All Phase) Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Number(All Phase)[Number(All Phase)]

<Output phase setting (phase number)>

All Phase: All Phase at once

L1:L1 Phase

L2:L2 Phase

L3:L3 Phase

Line: All Line at once

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Inst Nsel.vi

NF DP020AGS Inst Nsel.vi

NF DP020AGS Inst Nsel.vi

NF DP020AGS Inst Nsel.vi


NF DP020AGS Meas Inst Nsel.vi

Sets/gets the measurement query phase (phase number)

It specifies the phase to query the measured value for by the MEASure subsystem command.

* This command does not affect the measured value display phase

displayed in the LCD.


Connector Pane

NF DP020AGS Meas Inst Nsel.vi


Front Panel

NF DP020AGS Meas Inst Nsel.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cenum

Input Data Type(Input)[Input Data Type(Input)]

Specifies the value to be set.

input:Number(L1) Specified value

Max : Maximum Value

Min : Minimum Value

cenum

Number(L1)[Number(L1)]

<Measurement query phase (phase number)>

L1:L1 Phase

L2:L2 Phase

L3:L3 Phase

L1-L2:L1-L2 Line

L2-L3:L2-L3 Line

L3-L1:L3-L1 Line

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Meas Inst Nsel.vi

NF DP020AGS Meas Inst Nsel.vi

NF DP020AGS Meas Inst Nsel.vi

NF DP020AGS Meas Inst Nsel.vi


NF DP020AGS Outp Pon.vi

Sets/gets the output at power-on


Connector Pane

NF DP020AGS Outp Pon.vi


Front Panel

NF DP020AGS Outp Pon.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the output at power-on

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

Query[Query]

Measurement Frequency

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Outp Pon.vi

NF DP020AGS Outp Pon.vi


NF DP020AGS RST.vi

Initializes the setting


Connector Pane

NF DP020AGS RST.vi


Front Panel

NF DP020AGS RST.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error In[Error In]

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[Error OUT]

Block Diagram

NF DP020AGS RST.vi


NF DP020AGS Syst Beep Stat.vi

Sets/gets the operation beep


Connector Pane

NF DP020AGS Syst Beep Stat.vi


Front Panel

NF DP020AGS Syst Beep Stat.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

Read(F)[Read(F)]

Read : True

Default :False

cbool

State(ON)[State(ON)]

Sets the beep

0/OFF:Disable 1/ON:Enable

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

idbl

Query[Query]

Store the query results.

Read(F)

True : Query Results

False : Disable

istr

Read Data txt[Read Data txt]

Read(F):True Text data output

Read(F):False Do nothing

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Beep Stat.vi

NF DP020AGS Syst Beep Stat.vi


NF DP020AGS Syst Err.vi

Gets the error queue output


Connector Pane

NF DP020AGS Syst Err.vi


Front Panel

NF DP020AGS Syst Err.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error IN[error in (no error)]

error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

ii32

ErrorNo[ErrorNo]

Return Error code

istr

Error[Error]

Error Message

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error OUT[error out]

error out passes error or warning information out of a VI to be used by other VIs.

Right-click the control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.


Block Diagram

NF DP020AGS Syst Err.vi

NF DP020AGS Syst Err.vi

NF DP020AGS Syst Err.vi


NF DP020AGS Close.vi

Close communication with the instrument


Connector Pane

NF DP020AGS Close.vi


Front Panel

NF DP020AGS Close.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cerrcodeclst

Error In[Error In]

ierrcodeclst

Error Out[Error Out]

Block Diagram

NF DP020AGS Close.vi


NF DP020AGS Initialize.vi

Performs Initialization with return ID

Can specify whether to return the ID.


Connector Pane

NF DP020AGS Initialize.vi


Front Panel

NF DP020AGS Initialize.vi


Controls and Indicators

cvsrn

VISAsession[VISAsession]

A unique reference to an instrument I/O session.

cbool

ID Check(T)[ID Check(T)]

Specify whether to check the ID. T=Check F=Do nothing

cbool

Reset(T)[Reset(T)]

Specify whether to execute reseting T=Reset F=Do nothing

cerrcodeclst

Error In[Error In]

istr

ID[ID]

ID Check(T):True Return ID

ivsrn

CopyVISAsession[CopyVISAsession]

A unique reference to an instrument I/O session.

ierrcodeclst

Error Out[Error Out]

Block Diagram

NF DP020AGS Initialize.vi

NF DP020AGS Initialize.vi

NF DP020AGS Initialize.vi

NF DP020AGS Initialize.vi