Output Voltage and
Output Frequency |
|
|
|
Equipped for a wide range of
output voltages and output frequencies.
Wide range of output voltage and
frequency can offer versatile applications
such as frequency converter for
domestic,voltage change for overseas
equipment, and also to testing aircraft and
vessel's appliance, etc.
|
Output
Voltage Range |
Resolution
|
100V range : 0V
to 150.0V |
0.1V |
200V range : 0V
to 300.0V |
0.1V |
In three phase
and single phase three wire
modes, settings can be made by
phase voltage or line
voltage(resolution 0.2V). |
Output Frequency
Range |
Resolution |
5.0Hz to 550.0Hz
|
0.1V |
|
|
|
DC Output |
|
|
|
Appropriate for DC/DC
converter testing
Permits 0V to +424V output
voltage(0.1V resolution), +9A maximum
current (at 2kVA), and 900VA maximum power
(at 2kVA) DC output.
A single unit can be used as an AC power
supply or as a DC power supply.
|
|
|
Output current
during low power factor
load |
|
|
|
High stability mode secures
the performance of L, C load
Load power factor is guaranteed
at 0-1 (lead, delay). Provides 100% rated
current even during power factor 0, so
there's no problem running fluorescent
lights, switching regulator, and so forth.
|
|
|
Measurement
Function |
|
|
|
Free from external measuring
instruments
AC
|
Voltage(rms, peak), Current(rms,
peak), Effective power,
Voltampere, Power factor, Peak
current holding
*Phase voltage an line voltage
can be displayed in three phase
mode and single phase three wire
mode. |
DC
|
Voltage,
Current, Electrical power, peak
curent holding |
|
|
|
Failure Diagnosis
Function |
|
|
|
These power supplies conduct their own
failure diagnoses checks during power
start-up. If a problem is detected during
start-up, a warning message is displayed and
the flow of electricity to main electrical
parts is cut off to prevent the problem from
spreading. |
|
|
Protection
function |
|
|
|
Built-in 7 system protection function
safeguards load and power supply from such
problems as output short circuits, over
current ambient temperature rises, and line
voltage drops. Momentarily limits output in
the case of temporary over current, etc.
Automatically recover to normal output after
the problem has been corrected. |
Check items
|
Output current, Output voltage,
Input voltage abnormality of
power amplifier,Over-current of
power amplifier, Overheat of
internal heat sink,Operation
stop of DC power supply,
Operation stop of power
amplifier |
|
|
|
Memory
function |
|
|
|
This function can memorize (store) and
easily recall 10 panels of setting status
such as output voltage, frequency, etc. And
also it can recall quickly frequent used
setting through preset keys. |
|
|
External Ten-Key
Input |
|
|
|
Easy and convenient for
setting change and inspection work
|
By connecting the ten-key pad to
the front panel, you can input numeric
values through a ten-key pad as well as by
the dial. It can also be used as a "Recall
panel" for recalling settings programmed in
memory, making it convenient for inspection
operations on production lines and so forth.
*Ten-Key pad optional. |
|
|
Plus : |
|
|
|
Line
synchronization output
|
Provides AC output which is
synchronized power supply line
frequency by line
synchronization output function
|
Limiter
function |
Maximum output voltages as well
as maximum and minimum
frequencies can be preset with
the limiter function. |
Start phase
setting function |
Start
phase at Output ON can be set to
90° units through input
phase setting function. Comes in
handy when evaluating in rush
current on equipment under test.
|
Key lock
function |
Equipped with key lock functions
which allow you to nullify panel
key operation
|
Buzzer
|
Warning buzzer notifies you of
erroneous operation and overload
protection status. |
|
|
|